Enterprise Data Center Servers
Run virtualization, transactional databases, and enterprise applications on dual AMD EPYC 9004 or dual 5th Gen Intel Xeon Scalable processors, with up to 3TB of DDR5 ECC memory and PCIe Gen 5 NVMe storage configured in RAID 10.
Dual 25Gbps redundant uplinks connect the server to a network using a Tier-1 carrier mix. Automated PXE provisioning supports repeatable operating system deployment. A 100% hardware replacement SLA within two hours defines the hardware service commitment, subject to the scope and measurement terms in the service agreement.
Select the configuration against your application’s working set, sustained I/O demand, network traffic, and recovery requirements. Core count and interface speed alone do not establish production capacity.
Request a server configuration and SLA review.
CPU | Max RAM per server | Storage architecture | Storage IOPS | Network uplinks |
|---|---|---|---|---|
2 × AMD EPYC 9004 processors using dual-socket-capable SKUs | Up to 3TB DDR5 ECC | PCIe Gen 5 NVMe array in RAID 10 | Random read and write IOPS require validation for the selected array | 2 × 25Gbps redundant uplinks |
2 × 5th Gen Intel Xeon Scalable processors | Up to 3TB DDR5 ECC | PCIe Gen 5 NVMe array in RAID 10 | Random read and write IOPS require validation for the selected array | 2 × 25Gbps redundant uplinks |
Enterprise Server Configuration Matrix
enterprise-data-center-servers.pdfThe 3TB figure is the stated configuration ceiling for this offering. Actual memory capacity and speed depend on the motherboard, processor SKU, qualified DIMMs, and population rules.
Storage IOPS depend on the SSD model, drive count, RAID implementation, block size, queue depth, and read/write mix. No numeric array result is specified here.
Compute and Memory Architecture
Dual Processor Platforms
AMD EPYC 9004 processors support 12 DDR5 memory channels per socket. 5th Gen Intel Xeon Scalable processors support eight channels per socket. Both processor families support PCIe 5.0, providing an interface for compatible NVMe drives and network adapters. Available device connectivity depends on the server’s lane allocation, risers, and backplane. amd.com
Choose CPU SKUs according to application behavior. Concurrent virtual machines and parallel services need sufficient aggregate compute capacity. Applications with serial execution paths may respond more to per-core performance. Per-core software licensing can also change the economics of a higher-core-count configuration.
Dual-socket systems require NUMA-aware placement: keep a workload’s memory close to the CPU executing it where practical. Validate VM sizing, memory placement, and I/O locality with the intended hypervisor or operating system before setting consolidation targets.
DDR5 ECC Memory and Data Integrity
ECC memory stores additional check information that the memory controller uses to detect and correct supported error patterns. Common SECDED protection corrects single-bit errors and detects double-bit errors. More extensive correction depends on the processor, DIMM organization, and enabled platform features. Kingston Technology
Correcting a recoverable memory error can prevent an altered bit from reaching a database buffer, application object, or virtual machine. Detecting an uncorrectable error allows the system to flag unreliable data, although recovery may require terminating a workload or restarting the server.
DDR5 on-die ECC operates within individual DRAM chips. It does not replace server ECC protection across the memory interface. Specify ECC-qualified DIMMs and monitor corrected-error trends so recurring faults can inform component replacement. Kingston Technology
Memory Capacity and Channel Population
Up to 3TB of RAM provides capacity for large database working sets, in-memory processing, and dense VM deployments. Keeping frequently accessed data in memory can reduce storage reads when the application’s access pattern permits it.
Populate memory channels according to the platform’s documented rules. A capacity target and a bandwidth target are separate requirements: DIMM placement, modules per channel, and supported operating speed affect the result. Reserve memory for the host, management services, and the application’s expected growth. Kingston Technology
NVMe Storage and RAID 10
Read and Write IOPS Under Concurrent Load
NVMe uses submission and completion queues that support parallel I/O processing. This queue architecture allows multiple CPU cores and workloads to submit storage operations concurrently, reducing contention associated with a shared command path. nvmexpress.org
Higher sustained random-read IOPS can reduce storage queueing during index lookups, cache misses, and concurrent VM activity. Sustained write IOPS matter for ingestion, updates, and background writeback. For transaction logs and synchronous writes, completion latency and write durability are also decisive.
PCIe Gen 5 describes interface capability. It does not establish a drive’s sustained random IOPS or an array’s application response time. NAND behavior, controller firmware, RAID processing, thermal limits, and workload concurrency all affect delivered performance.
RAID 10 Capacity and Failure Behavior
Conventional RAID 10 stripes data across mirrored drive pairs. With equal-capacity drives and two-way mirroring, nominal usable capacity is approximately 50% of installed raw capacity before filesystem and other overhead. A four-drive array of 3.84TB SSDs, for example, provides approximately 7.68TB of nominal usable capacity. Dell United Kingdom
Reads can be distributed across mirror members when the implementation supports it. Writes must update both copies, so application write IOPS cannot be inferred by adding individual drive specifications. RAID 10 avoids parity calculations, but its performance still depends on the storage stack and workload.
The array can tolerate one failed drive in each mirror pair; losing both members of the same pair can cause data loss. Rebuild activity consumes I/O capacity. Maintain separate backups and application recovery procedures for deletion, corruption, and wider system failures. Dell United Kingdom
Performance Validation
Evaluate the complete array using a workload that represents production demand. A useful benchmark report records:
- Random-read, random-write, and mixed-workload IOPS, with block size and read/write ratio stated.
- Queue depth, worker count, test duration, and whether host caching is bypassed.
- Sustained performance after SSD preconditioning.
- Average and p95/p99 latency, alongside sequential throughput where relevant.
- Drive models, firmware, RAID implementation, filesystem, and write-cache policy.
Tools such as fio expose workload, queue-depth, latency, and steady-state controls for this purpose. For synchronous database workloads, also validate durable-write behavior and application-level latency. Fio 3.42-115-gcd29 documentation
Network Connectivity
Dual 25Gbps Redundant Uplinks
Two 25Gbps uplinks provide separate physical links for network resilience. Their usable capacity depends on the configured forwarding and failover mode.
In an active/standby arrangement, one 25Gbps link carries traffic while the other provides failover. With compatible link aggregation, concurrent flows may use both links; a typical single flow remains limited to one member link. The Linux Kernel documentation
Verify the upstream topology and failure detection. Links connected to the same switch can share a switch failure domain, and two ports on one adapter can share an adapter failure domain. Define the required path separation and test failover against the application’s tolerance for interruption.
Tier-1 Carrier Mix
The stated carrier mix provides upstream connectivity for external traffic. Evaluate its value against your actual destinations and traffic patterns: carrier classification alone does not establish latency, packet loss, or route diversity.
Request the carrier roster, committed bandwidth, traffic policy, and routing arrangements for the selected location. Distinguish the server’s 25Gbps port rate from committed internet throughput and measured end-to-end transfer performance.
Chassis Power Delivery
Redundant Power Supplies
For workloads requiring chassis power redundancy, specify two hot-swappable PSUs operating in a validated 1+1 configuration. Either PSU must support the complete configured chassis load at the available input voltage, including CPU, memory, storage, fans, and expansion cards.
In that configuration, one PSU can maintain operation if the other fails. A failed module can be replaced while the server remains powered, following the chassis manufacturer’s procedure. Installing two PSUs is insufficient if the configuration requires both to meet its load. Dell US
Independent A and B Feeds
Connect the PSU inputs to separate A and B power paths when feed redundancy is required. With appropriately sized supplies and independent upstream paths, the server can continue operating through the loss of one PSU, cord, PDU, or feed. Connecting both supplies to one PDU leaves that PDU as a shared failure point. support.hpe.com
Confirm PSU ratings, redundancy mode, and the actual feed arrangement in the configuration proposal. PSU redundancy addresses power delivery; motherboard and chassis-level failures still require service or workload failover.
Deployment and Hardware Service
Automated PXE Provisioning
Automated PXE provisioning boots the server into a network installation environment and supports unattended operating system deployment. It provides a repeatable starting point for new installations and rebuilds, reducing manual installation steps and configuration variation.
Define the approved image, storage layout, network settings, and post-install validation before deployment. Application configuration, secrets, monitoring enrollment, and data restoration remain part of the wider provisioning workflow. Confirm image compatibility and the provisioning process for the selected operating system.
Two Hour Hardware Replacement SLA
Hardware replacement commitment: 100% within two hours, as defined by the applicable SLA.
The service agreement must identify the covered components, the event that starts the two-hour clock, the replacement completion criteria, and the remedy for a missed commitment. These definitions make the service promise measurable during an incident.
Hardware replacement time is one input to recovery planning. Operating system repair, RAID rebuilds, backup restoration, and application validation may extend the time required to restore service. Set application recovery objectives separately and use clustering or replication where the workload requires continuity during server repair.
Match the Configuration to Your Workload
Virtualization and Container Hosts
Size compute and memory against active workload demand, expected concurrency, and capacity needed during maintenance or a host failure. Validate storage latency during simultaneous boot, migration, and background activity before committing to a VM density target.
Transactional Databases
Prioritize database working-set capacity, durable-write latency, sustained mixed I/O, and CPU licensing cost. Test checkpoints and log activity alongside normal queries so background operations are represented in the acceptance criteria.
Analytics and Data Processing
Evaluate memory bandwidth, scan throughput, concurrency, and network movement together. A compute-heavy stage and an I/O-heavy stage may require different resources; size the server against the stage that constrains completion time.
Request Your Enterprise Server Configuration
Send your workload profile, preferred processor platform, memory target, usable storage requirement, read/write mix, latency objectives, and network demand.
Request a proposal that states the CPU SKUs, DIMM population, SSD models and count, RAID implementation, PSU arrangement, network topology, provisioning scope, and hardware replacement SLA. Use those details to establish acceptance criteria and compare configurations on measurable operating requirements.
Request a configuration proposal and review the two-hour hardware replacement SLA.
Enterprise Data Center Servers: Frequently Asked Questions
Technical answers for CTOs and IT Infrastructure Managers evaluating compute capacity, memory integrity, storage performance, network resilience, and hardware service commitments.
Enterprise Server Configuration Matrix
CPU | Max RAM per server | Storage architecture | Storage IOPS | Network uplinks |
|---|---|---|---|---|
2 × AMD EPYC 9004 processors using dual-socket-capable SKUs | Up to 3TB DDR5 ECC | PCIe Gen 5 NVMe array in RAID 10 | Read/write IOPS require measurement for the selected array and workload | 2 × 25Gbps redundant uplinks |
2 × 5th Gen Intel Xeon Scalable processors | Up to 3TB DDR5 ECC | PCIe Gen 5 NVMe array in RAID 10 | Read/write IOPS require measurement for the selected array and workload | 2 × 25Gbps redundant uplinks |
Deployment: Automated PXE provisioning.
Hardware service: 100% hardware replacement SLA within two hours, subject to the scope and measurement terms in the service agreement.
The 3TB figure is the configuration ceiling for this offering. Delivered memory capacity and speed depend on the selected chassis, CPU SKUs, qualified DIMMs, and population rules. Numeric storage IOPS must be established through a documented array benchmark.
Compute and Memory
1. How should we choose between dual AMD EPYC 9004 and dual 5th Gen Intel Xeon Scalable processors?
Choose the platform against application throughput, per-core performance, memory bandwidth, software certification, and licensing cost. AMD EPYC 9004 processors provide 12 DDR5 memory channels per socket; 5th Gen Intel Xeon Scalable processors provide eight. Both families support PCIe Gen 5. A dual-processor AMD configuration requires SKUs that support two sockets. amd.com
For virtualization, assess aggregate compute demand and workload concurrency. For databases licensed per core, compare transaction throughput against total licensing cost. Benchmark the proposed CPU SKUs with the intended software stack; channel count and core count alone do not establish application performance.
2. How does DDR5 ECC memory protect databases and virtual machines?
ECC memory stores check bits alongside data. The memory controller uses them to detect and correct supported error patterns. Common single-error correction and double-error detection, or SECDED, corrects single-bit errors and detects double-bit errors. Additional correction capabilities depend on the platform and DIMM organization. Kingston Technology
Correcting a recoverable error can prevent an altered value from reaching a database buffer or virtual machine. An uncorrectable error may require workload termination or a server restart. Monitor corrected-error trends to identify recurring DIMM faults.
DDR5 on-die ECC operates inside individual DRAM chips. Server ECC adds protection for data transferred between memory and the processor; on-die correction alone does not provide that protection. Kingston Technology
3. What does support for up to 3TB of RAM mean for workload sizing?
Up to 3TB of DDR5 ECC RAM is the stated maximum per server for this offering. Select capacity against the database working set, active VM allocations, host overhead, and expected growth. Keeping frequently accessed data in memory can reduce storage reads when the application’s access pattern permits it.
Memory bandwidth also depends on channel population and supported DIMM speed. Follow the motherboard’s qualified configuration rules. In dual-socket systems, use NUMA-aware placement to keep workload memory close to the processor executing it where practical. The configuration proposal should identify DIMM capacity, quantity, placement, and operating speed.
Storage Performance and Data Protection
4. What read and write IOPS can we expect from the PCIe Gen 5 NVMe array?
Array IOPS must be measured for the selected SSD models, drive count, RAID implementation, and workload. NVMe supports multiple submission and completion queues, allowing concurrent I/O from multiple CPU cores. This architecture supports parallel storage access under database and virtualization workloads. NVM Express
Sustained random-read IOPS affect index lookups and cache misses. Sustained random-write IOPS affect updates, ingestion, and background writeback. Transaction logs also require low durable-write latency. PCIe Gen 5 specifies interface capability; delivered IOPS depend on the complete storage stack.
Request a benchmark stating block size, read/write mix, queue depth, worker count, cache policy, SSD preconditioning, and test duration. Review sustained IOPS alongside p95/p99 latency, and validate synchronous writes against the application’s durability requirements. Fio 3.42-115-gcd29 documentation
5. How does RAID 10 affect usable capacity and disk failure tolerance?
Conventional RAID 10 stripes data across mirrored drive pairs. With equal-capacity drives and two-way mirroring, nominal usable capacity is approximately 50% of raw capacity before filesystem and other overhead. As a capacity example, four 3.84TB SSDs provide approximately 7.68TB of nominal usable capacity. Dell United Kingdom
The array can remain available after one drive fails in each mirror pair. Losing both members of the same pair can cause data loss. Writes update both copies, and rebuilds consume I/O capacity. Include degraded-array and rebuild performance in acceptance testing where availability matters. Separate backups and tested restoration procedures address deletion, corruption, and wider system failures.
Network and Chassis Power
6. Do dual 25Gbps uplinks provide 50Gbps of usable bandwidth?
Usable bandwidth depends on the forwarding mode. In active/standby mode, one 25Gbps link carries traffic while the second provides failover. With supported link aggregation and appropriate traffic distribution, multiple concurrent flows may use both links. A typical single flow remains limited to one 25Gbps member link, before protocol overhead. The Linux Kernel documentation
Resilience also depends on physical topology. Two ports on one adapter share an adapter failure domain; two links to one switch share a switch failure domain. Specify the required adapter and switch separation, confirm the bonding or aggregation mode, and test failover against the application’s interruption tolerance.
7. How should we evaluate the Tier-1 carrier mix?
Assess connectivity against the locations and networks your applications serve. Request the carrier roster, routing policy, committed internet bandwidth, traffic allowances, and upstream path diversity for the selected data center. Measure latency, packet loss, and jitter to representative destinations under expected traffic conditions.
The dual 25Gbps specification identifies server uplink rates. Internet transfer performance also depends on purchased bandwidth, routing, congestion, the remote endpoint, and application behavior. Include throughput commitments and relevant network service terms in the proposal so procurement can compare connectivity on measurable requirements.
8. How should power delivery redundancy be configured at the chassis level?
Specify two hot-swappable power supplies in a validated 1+1 configuration, with either unit able to support the complete configured chassis load at the supplied input voltage. That load includes CPUs, memory, storage, fans, and expansion cards. With sufficient remaining capacity, one PSU can sustain operation after the other fails, allowing replacement according to the chassis manufacturer’s procedure. Dell
For feed redundancy, connect the PSUs to separate PDUs on independent A and B power paths. This arrangement can preserve power through the loss of one PSU, cord, PDU, or feed. Confirm the PSU ratings, redundancy mode, and upstream feed independence in the proposal. Power redundancy does not cover motherboard or shared chassis component failures. Managing HPE Serviceguard for Linux A.12.80.00
Deployment and Hardware Service
9. What does automated PXE provisioning include?
PXE provisioning boots the server into a network installation environment. Combined with an unattended installation configuration, it supports repeatable operating system deployment and rebuilds with fewer manual installation steps. Red Hat Documentation
Define the approved operating system image, boot mode, storage layout, network settings, and post-install checks before deployment. The agreed scope should also identify responsibility for application installation, credential configuration, monitoring enrollment, and data restoration. Confirm operating system and driver compatibility for the selected hardware, along with the expected handover time.
10. How is the 100% hardware replacement SLA within two hours measured?
The stated service commitment is 100% hardware replacement within two hours, as defined by the applicable SLA. The agreement must specify covered components, the event that starts the clock, replacement completion criteria, applicable exclusions, and the remedy for a missed commitment. These terms allow infrastructure teams to measure service delivery during an incident.
Application recovery may take longer because RAID rebuilds, operating system repair, backup restoration, and application validation can follow replacement. Set the recovery time objective (RTO) and recovery point objective (RPO) separately. Where applications must remain available during host repair, design and test workload failover across independent servers.
Request an Enterprise Server Configuration
Submit your workload profile, preferred processor platform, memory target, usable storage requirement, I/O mix, latency objectives, network demand, and recovery requirements.
Request a configuration proposal with the complete hardware specification, storage benchmark criteria, power and network topology, provisioning scope, and two-hour hardware replacement SLA.
Enterprise Data Center Servers: Deployment and Support
Dual-processor infrastructure with defined provisioning and hardware replacement commitments.
Deploy virtualization hosts, databases, and enterprise applications on dual AMD EPYC 9004 or dual 5th Gen Intel Xeon Scalable platforms. Configurations support up to 3TB DDR5 ECC RAM, PCIe Gen 5 NVMe arrays in RAID 10, and dual 25Gbps redundant uplinks through a Tier-1 carrier mix.
Enterprise Server Configuration Matrix
CPU | Max RAM per server | Storage IOPS | Network uplinks |
|---|---|---|---|
2 × AMD EPYC 9004, using dual-socket-capable SKUs | Up to 3TB DDR5 ECC | Read/write IOPS require array benchmarking | 2 × 25Gbps redundant uplinks |
2 × 5th Gen Intel Xeon Scalable | Up to 3TB DDR5 ECC | Read/write IOPS require array benchmarking | 2 × 25Gbps redundant uplinks |
The configuration proposal specifies qualified DIMM population, SSD models, drive count, and RAID implementation.
Architecture and Failure Protection
ECC Memory Integrity
Server ECC uses check bits to correct supported memory errors before affected data reaches applications. Common SECDED protection corrects single-bit errors and detects double-bit errors, reducing the risk of silent corruption in database buffers and virtual machines. DDR5 on-die ECC operates within individual DRAM chips; server ECC provides additional protection across the memory interface. Kingston Technology
NVMe Read and Write Performance
NVMe submission and completion queues support parallel I/O. Sustained random-read IOPS influence index lookups and cache misses; random-write IOPS influence updates and ingestion. Validate the RAID 10 array’s IOPS and p95/p99 latency using stated block sizes, queue depths, and read/write ratios. PCIe Gen 5 interface capability alone does not establish array performance. NVM Express
Chassis Power Redundancy
For power continuity, specify two hot-swappable PSUs in validated 1+1 mode, each capable of carrying the complete configured chassis load at the supplied voltage. With independent A/B feeds and separate PDUs, the surviving power path can sustain operation during a single PSU or feed failure. Confirm this topology in the proposal. Dell
Provisioning and Hardware Service
Automated PXE Provisioning
PXE provisioning supports repeatable operating system installation from an approved network image. Agree the operating system, storage layout, network settings, and post-install validation before deployment. docs.redhat.com
Two-Hour Hardware Replacement SLA
The stated commitment is 100% hardware replacement within two hours, as defined by the applicable SLA. Confirm covered components, clock-start conditions, replacement completion criteria, and remedies. Application recovery may also require RAID rebuilds, data restoration, and service validation.
Request a configuration and support scope review.
Enterprise Server Configuration Matrix
CPU | Max RAM per server | Storage IOPS | Network uplinks |
|---|---|---|---|
2 × AMD EPYC 9004, using dual-socket-capable SKUs | Up to 3TB DDR5 ECC | Read/write IOPS require array benchmarking | 2 × 25Gbps redundant uplinks |
2 × 5th Gen Intel Xeon Scalable | Up to 3TB DDR5 ECC | Read/write IOPS require array benchmarking | 2 × 25Gbps redundant uplinks |
Storage: PCIe Gen 5 NVMe arrays in RAID 10. Deployment: Automated PXE provisioning. Hardware service: 100% hardware replacement within two hours, as defined by the applicable SLA.
Technical Benefits for the Product Page
ECC Memory Integrity
Common SECDED protection corrects single-bit memory errors and detects double-bit errors, reducing the risk of corrupted values reaching database buffers and virtual machines. DDR5 on-die ECC protects individual DRAM chips; server ECC adds protection across the memory interface. www.kingston.com
NVMe Read and Write Performance
NVMe’s parallel queues support concurrent storage access. For storage-bound workloads, sustained random-read IOPS can reduce queueing during index lookups; random-write IOPS support updates and ingestion. Validate array IOPS and p95/p99 latency using documented block sizes, queue depths, and read/write ratios. PCIe Gen 5 alone does not establish delivered performance. nvmexpress.org
Chassis Power Redundancy
Specify two hot-swappable PSUs in validated 1+1 mode, with either unit sized for the complete configured chassis load at the supplied voltage. Independent A/B feeds and separate PDUs can preserve power through a single PSU or feed failure. Confirm the PSU ratings and feed topology in the configuration proposal. www.dell.com
Enterprise Data Center Servers: Product Tags
Product Tags
Category | Product tags |
|---|---|
Product and compute | Enterprise Data Center Servers, Enterprise Servers, Dual-Processor Servers, AMD EPYC 9004, 5th Gen Intel Xeon Scalable |
Memory and storage | DDR5 ECC Memory, Memory Error Correction, Up to 3TB RAM, PCIe Gen 5 NVMe, RAID 10 Storage |
Network | Dual 25Gbps Uplinks, Network Redundancy, Tier-1 Carrier Mix |
Provisioning and service | Automated PXE Provisioning, Server Deployment, Hardware Replacement SLA, 2-Hour Hardware Replacement |
Workloads | Virtualization Hosts, Database Servers, Enterprise Applications |
Enterprise Server Configuration Matrix
CPU | Max RAM per server | Storage IOPS | Network uplinks |
|---|---|---|---|
2 × AMD EPYC 9004, using dual-socket-capable SKUs | Up to 3TB DDR5 ECC | Read/write IOPS require array benchmarking | 2 × 25Gbps redundant uplinks |
2 × 5th Gen Intel Xeon Scalable | Up to 3TB DDR5 ECC | Read/write IOPS require array benchmarking | 2 × 25Gbps redundant uplinks |
Storage: PCIe Gen 5 NVMe arrays in RAID 10. Deployment: Automated PXE provisioning. Service: 100% hardware replacement within two hours, as defined by the applicable SLA.
Technical Basis for Tagging
ECC Memory Error Correction
Common SECDED protection corrects single-bit memory errors and detects double-bit errors, reducing the risk of corrupted values reaching database buffers and virtual machines. DDR5 on-die ECC operates within individual DRAM chips; server ECC adds protection across the memory interface. Kingston Technology
NVMe Read and Write IOPS
NVMe’s parallel submission and completion queues support concurrent storage access. Sustained random-read IOPS affect index lookups and cache misses; random-write IOPS affect updates and ingestion. Validate the selected RAID 10 array using documented block sizes, queue depths, read/write ratios, and latency percentiles before assigning performance claims. NVM Express
Chassis Power Redundancy
A validated 1+1 configuration uses two PSUs, either capable of supplying the complete configured chassis load at the supplied voltage. Hot-swap support allows a failed PSU to be replaced while the other sustains operation. Independent A/B feeds through separate PDUs can preserve power during a single PSU or feed failure. Dell
Conditional tags: 1+1 PSU Redundancy, Hot-Swappable PSUs, A/B Power Feeds.
Apply these power tags after confirming PSU ratings, chassis redundancy mode, hot-swap support, and feed independence in the configuration proposal.